Emergency rescue board for motors up to 20A with VVVF doors management
RTP100
CONTROL / Inversor y vuelta al piso

— Suitable for Emergency Rescue of Traction AC2 Speed or Traction Geared VVVF.
— Management of motors up to 20A.
— Grid Voltage from 3x230Vac to 3×400 Vac 50/60Hz +/-10%.
— Board power supply 230Vac 50/60Hz +/-10%.
— Integrated battery charger 54Vdc – 200mA able to manage up to 4 batteries in series – 12Ah max.
— Diagnostic LEDs on board.
— Removable keypad for advanced diagnostic.
— General regulation by trimmer and switch on the board.
— Maximum output power 200VA.
— Single access Automatic Door Operator VVVF (single-phase).
— Selection of car recommended direction.
— Max duration of rescue maneuvre 5 min.
— Safety chain voltage AC or DC.
— Motor voltage and frequency manually adjustable.
— Stop delay and door opening time manually adjustable.
— Dimensions: 280mm x 212mm.
Conexión a tierra
¿Has optado por instalar los productos electrónicos de Vega en una placa metálica?
Atención: conecta las placas al sistema de toma de tierra. De este modo, evitarás posibles fallos de funcionamiento o daños en los dispositivos electrónicos.
Limpieza del producto
¿Cómo limpiar los pulsadores de Vega? Con un paño de algodón y agua caliente.
Precaución: no utilizar productos químicos, especialmente para las superficies de plástico. Muchos productos de Vega están fabricados en policarbonato, ABS, metacrilato o nailon 66. Evita los productos de limpieza que contengan (incluso en pequeña cantidad) amoniaco, hidrocarburos, sosa cáustica, ácido clorhídrico, ácido nítrico, ácido acético, alcohol etílico, alcohol metílico.