VG-RTP
Emergency rescue board for motors up to 35A with 3-phase /VVVF doors management.
- Hauptfunktionen
- Technical features
- Warning Grounding System
- Suitable for Emergency Rescue of Traction AC2 Speed or Traction Geared VVVF.
- Management of motors up to 35A.
- Grid Voltage from 3x230Vac to 3x400 Vac 50/60Hz +/-10%.
- Board power supply 230Vac 50/60Hz +/-10%.
- Integrated battery charger 54Vdc – 200mA able to manage up to 4 batteries in series – 12Ah max.
- Diagnostic LEDs on board.
- Removable keypad for advanced diagnostic.
- General regulation by trimmer and switch on the board.
- Maximum output power 600VA.
- Single access Automatic Door Operator 3-phase or VVVF (single-phase or threephase).
- Selection of car recommended direction.
- Max duration of rescue manoeuvre 5 min.
- Safety chain voltage AC or DC.
- Motor voltage and frequency manually adjustable.
- Stop delay and door opening time manually adjustable.
- Dimensions: 280mm x 212mm.
WARNING GROUNDING SYSTEM
In case of installation of the device on a metal fixture, it is strongly recommended to connect the fixture to the grounding system, to avoid malfunction or damage to the electronic device installation.