B-Lift-240
Lift light curtains compliant to EN81-20/50 Standard, with self test thanks to the Vega integrated system, without power supply box.
- Focus
- Main Features
- Models
- Mechanical profile
- Warning Grounding System
|
UP TO 194 BEAMS |
VEGA INTEGRATED SYSTEM (CONTINUOS TEST ON THE LIGHT CURTAIN) |
|
WITHOUT EXTERNAL POWER SUPPLY UNIT |
- Size (width x depth x height): 10x28x2000mm
- Detecting Height: 20mm to 1872mm.
- Number of IR diodes: 40.
- Scan beams (distance > 400mm): 194 beams.
- Scan beams (distance < 400mm): 118 beams.
- Opening: 0mm - 4000mm.
- Ideal for both static and dynamic mounting.
- Light Immunity: 100,000 LUX.
- Operating Temperature: -20°C ~ +65°C.
- Buzzer: After continuous detection for 15s buzzer on (when BUZZER SWITCH=ON).
- Cable length: 4 mt.
- Standard Output: Relay.
- IP: 54.
- Can be connected to VEGA boards ((OPR520, OPR700, OPR800 or new CRB-LINK)) which test periodically the light curtains
Model |
B-LIFT-240 |
Power supply |
13-30 VDC |
WARNING GROUNDING SYSTEM
In case of installation of the device on a metal fixture, it is strongly recommended to connect the fixture to the grounding system, to avoid malfunction or damage to the electronic device installation.